Views: 48967

The CYANExpert 130

Product code : cy008

The CYANExpert 130

Quantity:


    The CYANExpert 130
    is a continuous loading, random access automatic biochemistry analyzer. It is our fastest, most convenient, precise and flexible analyzer so far. It includes numerous cost saving features and provides a lot of flexibility to the operator. The software has advanced data management and QC features. It carries out constant checks to increase the validity of the delivered results and to provide genuine walk-away time. During operations, real-time visual feedback is provided to the operator. The CYANExpert 130 will reduce the workload and increase the efficiency of your lab. The CYANExpert 130 is intended for expanding laboratories that focus on quality and perform up to 800 biochemical and immunoturbidimetric measurements per day.
    Cost savings:
    • Minimum reaction volume of 220 µl means a decreased costs per test
    • Fluid level detection eliminates testing errors due to empty water, washing solution, controls, calibrators, or sample or reagent containers
    • Washing station automatically washes the reaction cuvettes
    • Separate waste lines reduce hazardous waste
    • True walk-away automation optimizes the staff time
    • Auto sample re-run eliminates risk of human error
    • Low service requirements
    • Standby light status, reduces the power consumption and extends the lifespan of the lamp
    • Uses a no maintenance, high-precision pipetting diluter
    • Two sizes of reagent container reduce the dead volumes
    • Limited water consumption Convenience:
    • Onboard sample and calibrator dilution available
    • Analyzer auto-diagnostics provide accurate system information • No daily maintenance
    • Automatic standby function reduces the running costs
    • Password protected accounts let you work with different users, each with their own defined tasks and authorizations
    • Automatic system check reduces operator workload
    • Removable reagent tray permits overnight storage in the refrigerator under validated temperatures
    • All washed cuvettes are automatically tested with blank levels Real-time feedback:
    • Count-down timer to completion
    • Clear visual information
    • Real-time display of running status
    • Real-time monitoring of reagent residual volume
    • Real-time diagnosis of system working status
    Flexibility:
    • Up to 32 samples can be loaded continuously
    • Shorter turn around time (TAT) enables a patientfocused service
    • Priority for STAT tests
    • Universal sample carrousel loads the most common types of primary tubes
    • Eight wavelengths (340, 380, 405, 492, 510, 546, 576 & 620 nm filters) cover all clinical diagnostics kits
    • Five calculation methods (absorbance, endpoint, two-point, kinetic, bichromatic) and nine calibration methods (factor, calibrator, point-to-point, and multipoint calibration) provide plenty of processing options with one system
    • Three blank options (sample blank, reagent blank, and water) provide background correction of the reagent and sample coloration
    • Pre-heated sampling line reduces incubation and TAT time
    • Continuous loading
    • 120 reaction cuvettes for simultanious measurements Data management:
    • Sample and patient based identification allow quick queries and follow-up statistics
    • Sample and reagent barcode identification available as an option
    • LIS connectivity lets you push and pull data into the system using the ASTM standard
    • Access codes safeguard the system operation by authorized users only Quality Control:
    • Automatic generation of Levey-Jennings charts, running mean values and QC statistics
    • Automated QC interpretation and control the analyzer reduce the workload
    • Double beam optical system increases the measurement precision
    • Cuvettes are quality controlled after washing

    The Software
    The CYANExpert 130 is our fastest biochemistry analyzer. With 130 tests per hour in random access it offers a lot of flexibility. It is an effective and reliable analyzer with first class software. We see the software as the vital element of the CYANExpert 130. We have integrated everything we know into the programming. Our goal was to make it easy and intuitive for users to operate. The following examples highlight the sophistication of the CYANExpert 130 software:
    • The CYANExpert 130 checks on a per test basis if the volumes of reagent, washing solution, and sample available are sufficient to perform the test. This safeguard lets the operator handle other tasks while the analyzer is working. This safeguard increases productivity of the laboratory staff (multitasking becomes possible), reduces costs (as no analyses will be invalid due to a lack of washing solution, reagents, samples, etc.) and a higher reliability of the results (tests performed without sufficient reagents are excluded).
    • The barcode reader and connections to an LIS (Laboratory Information System) and HIS (Hospital Information System) the CYANExpert’s results can be delivered to all medical units in the medical facility.
    • Reporting is straightforward with the database management software.
    • The CYANExpert 130 is an intelligent system that performs self-checks.
    • The instrument performs sample re-runs and dilutions automatically according to the operator’s programming. These options allow the laboratory to validate the results better while reducing the workload.

    Software features:
    • Unlimited work list
    • Historical patient results database
    • Methods, calibrators, and controls database
    • Method programming includes control parameters
    • STAT samples
    • Quality control and visualization and printout of graphs (Levey-Jennings)
    • Sample pre-dilution and automatic dilution in rerun mode
    • Automatic rerun programmable
    • Reference values are user definable for serum and urine for child, female and male
    • Sample entry for serum/urine
    • Multipoint calibration curve (automatic dilution of master standard) and relative graphs
    • Bidirectional interface with host computer
    • Auto-diagnostics program for a system built of different modules
    • Communication: USB 1.1/2.0 full speed and RS-232
    • Operating system: Windows 7
    • Language: English, French; other languages on request
    • Screen resolution: 800 x 600 pixels

    Technical Specifications
    Measurements procedures:
    • Endpoint, fixed time, kinetic, bichromatic, absorbance and
    differential
    • Blank: water, reagent blank or sample blank
    • Calibration: factor, calibrator and multipoint
    • Up to three different reagent additions possible for each method
    • Samples can be loaded by single test or profile
    • 9 different calculation algorithms programmed for linear and non-linear multipoint analysis Photometer particulars:
    • Multi-wavelength double beam photometer with narrow band interference filters
    • Filters (8): 340, 380, 405, 492, 510, 546, 576, 620 nm
    • Halogen lamp 6V/10W (2000 hours)
    • Linear range: 0,0005 – 3,5000 Abs
    • Resolution: 0,0005 Abs
    • Drift: < 0,0001 Abs • Detector: Silicon diode
    • Automatic autozeroing on the sample and reference channel (double beam) Capacity:
    • 32 sample positions (4 racks with 8 positions) of 3 ml sample cups or primary tubes
    • 24 reagent containers (35 ml or 6 ml)
    • 12 positions for controls and calibrators Sampling:
    • High precision diluter module
    • Sample aspiration: 2-99 µl with 1 µl increments
    • Reagent 1 volume: 3-500 µl with 1 µl increments
    • Reagent 2 & 3 volumes: 3-330 µl with 1 µl increments
    • Minimum reaction volume: 220 µl
    • Maximum reaction volume: 550 µl
    • Precision: CV < 1% at 2 µl
    • Liquid level sensor
    • Preheated sampling line at 37°C
    • Automatic probe wash cycle in between tests to avoid cross-contamination
    Cuvettes:
    • 120 semi-disposable reading cuvettes (6 racks with 20 positions) with a 6 mm light path
    • Automatic washing and drying cycle by the washing station for reusing the cuvettes
    • Automatic QC of cuvettes after washing
    • Temperature controlled at 37°C Option:
    • Barcode reader for reagents and samples Operation:
    • Random access 130 tests/h
    • Runs clinical chemistry and turbidimetric tests
    • Large choice of Cypress Diagnostics reagents available
    • Up to 300 clinical applications programmable
    • STAT for emergencies
    Weight and dimensions: • 53 x 57 x 75 cm (H x W x L) • 37 Kg Operating environment: • In covered and dry places • Temperature: 18°C – 32°C
    • Relative humidity: 20%-85%
    • Stable surface (no vibrations)
    • > 10 cm around the instrument to permit air circulation Power: • 110/220 V – 47/63 Hz • 300 W
    • Advised: Electronic Stabilizer (> 1kW Power potential) No-Break Module (UPS - Uninterruptible Power Supply)
    Order code: • CY008 CYANExpert 130